3-2610-XX 2610 Dissolved Oxygen Sensor


Sensor Type: Luminescent dissolved oxygen sensor, Transmitter/Local Display: Optional, not required. Compatible with 8900 and SmartPro instruments, Communications Options: Modbus (RS485), 4 to 20 mA 3-2610-31 and -41, (S3 L) 3-2610-41, Maximum Cable Length: Up to 1219 m (4000 ft) (Modbus and 4 to 20...

WHERE TO BUY?
Overview
Specification
Overview
Signet 2724-2726 pH/ORP Electrodes

The Signet 2610 RDO® Pro is a rugged, reliable sensor designed to deliver accurate dissolved oxygen (DO) data across a wide measuring range while reducing maintenance costs. It features the latest optical technology for DO measurement and eliminates the replacement of membrane and reference solutions.

The Signet 2610 Optical Sensor Cap is calibrated at the factory and requires no field calibration. The optical measurement technology resists abrasion and bleaching, allowing for a long life in many harsh applications. The DO sensor has a built in Modbus RS485 and 4 to 20 mA current loop outputs for ease of interface to existing control systems. The 3-2610-41 version includes the Signet (S3L) digital interface for direct connection with the 9900 SmartPro™ Transmitter and 8900 Multi-Parameter Controller. Additional features include a 10 m (32.8 ft) cable with stripped and tinned ends as well as a titanium thermistor for improved compatibility in salt water applications.

Fields of Application:
  • Municipal and Industrial Wastewater Treatment
  • Drinking Water Reservoir Monitoring
  • Environmental Water Discharge Monitoring
  • Aquatic Life Support
Advantages:
  • Optical DO measurement, no flow requirements
  • Rugged construction
  • Calibration built into the measurement cap: 2% of range, 0 to 20 mg/L
  • One year measurement cap life
  • No membranes or filling solutions
  • Flexible communications, 4 to 20 mA, Modbus (RS485) or S3L
  • Measurement range: 0 to 20 mg/L, in-line or submersible
Standards:
  • CE
  • FCC
  • RoHS compliant
  • China RoHS
Specification
Sensor TypeLuminescent dissolved oxygen sensor
Transmitter/Local DisplayOptional, not required. Compatible with 8900 and SmartPro instruments
Communications OptionsModbus (RS485), 4 to 20 mA 3-2610-31 and -41, (S3 L) 3-2610-41
Maximum Cable LengthUp to 1219 m (4000 ft) (Modbus and 4 to 20 mA), 38 m (125 ft) (S3 L)
Internal Mounting Thread1¼ NPT
Power Requirements12 to 24 VDC ±10% regulated
4 to 20 mA output span0 to 20 mg/L
Salinity Range0 to 42 PSU, fixed or real-time capable
pH Range2 to10 pH
Barometric Range507 to 1115 mbar, fixed or real-time capable
Maximum Pressure300 psi
Range0 to 20 mg/L concentration, 0 to 200% saturation
Accuracy (DO)±0.1 mg/L, 0 to 8 mg/L, ±0.2 mg/L, 8 to 20 mg/L
Response Time of CapT90: 30 sec, T95: 37 sec @ 25 °C
Repeatability0.05 mg/L
Resolution0.01 mg/L
Wetted MaterialsABS, Titanium and FPM
Usage Life of Cap1 year from the first instrument reading
Shelf Life of Cap24 months from date of manufacture (install within 12 mo. of manufacture)
Operating Temperature0 °C to 50 °C (32 °F to 122 °F)
IP RatingIP-67 with cap off, IP-68 with cap installed
ComplianceHeavy industrial, IEC 61000-6-2:2005
Storage Conditions, Cap1 °C to 60 °C (33 °F to 140 °F), in factory container
Storage Conditions, Sensor-5 °C to 60 °C (23 °F to 140 °F)