GF Signet 3-2650-7 Amperometric chlorine electrode. material: pbt, accuracy: < 5 na or 1% of
Amperometric chlorine electrode. material: pbt, accuracy: < 5 na or 1% of for analytical process measurement
GF Signet 3-2650-7 is the Amperometric chlorine electrode. material: pbt, accuracy: < 5 na or 1% of for analytical process measurement.
GF Signet 3-2650-7 Amperometric chlorine electrode. material: pbt, accuracy: < 5 na or 1% of
GF Signet 3-2650-7 is the Amperometric chlorine electrode. material: pbt, accuracy: < 5 na or 1% of for analytical process measurement.
Specifications and Features
2650 Amperometric Electrode
The Signet 2650 Amperometric Electronics provide the polarization voltage and signal conditioning required by all Signet Amperometric Sensors. The 2650 Amperometric Electronics also relays important sensor information that is stored on a memory chip inside the sensor and displayed on the 3-8630-3P transmitter. Information includes factory calibration data, service life, calibration information and more.
Signet's patented DryLoc® connector provides a quick and secure connection to the sensor. Gold-plated contacts and an O-ring seal ensure a waterproof and reliable interconnect to the sensor.
Sensor maintenance, replacement and troubleshooting have never been easier. The DryLoc® electronics can be separated from the sensor, which allows the user to detect a faulty sensor, electronics or cable assembly.
Fields of Application:
- Water Distribution
- Ground Water
- Surface Water
- Gray Water Dechlorination
- HVAC
- Food and Beverage
- RO Membrane Protection
- Swimming Pools
- Aquariums
- Water Parks
Advantages:
- Conditions the signal from the 2630 Sensor and provides sensor-stored data to the Chlorine Transmitter
- Patented DryLoc® connector provides a quick and secure connection to the sensor
- Waterproof and reliable interconnect to the sensor
- Easy sensor replacement without running new cable
- Easy sensor removal for servicing
Standards:
- CE
- FCC
- China RoHS
- RoHS compliant
Product Details
- Manufacturer: GF Signet
- Part number: 3-2650-7
- Product type: Chlorine Electrode
Review range, materials and electronics compatibility.
| Compatibility | All Signet Amperometric DryLoc Sensors / Signet 3-8630-3P Chlorine Transmitter / All 3-4630 Chlorine panel assemblies |
|---|---|
| Mounting | DryLoc connection |
| Materials | Valox® (PBT) |
| Cable | 4.6 m (15 ft) 3 conductor shielded, 22 AWG |
| Electronics Accuracy | < 5 nA or 1% of reading, whichever is greater @ 25 °C over full input range |
| Temperature | ±1.0 °C (PT1000) over full operation range (when calibrated at ambient temperature) |
| Update Rate | 500 ms |
| Operational Range | ±450 nA |
| Resolution | 0.1 nA |
| Input Specifications Sensor | Raw signal |
| Input Specifications Temperature | PT1000 RTD |
| Output Specifications Digital (S3 L) | Serial ASCII, TTL level 9600 bps |
| Output Specifications Max. Cable Length | 30 m (100 ft) |
| Output Specifications Power Supply Input | Digital (S3 L) mode / 5 to 6.5 V ± 10%, 3 mA max. |
| Operating Temperature | 0 °C to 85 °C (32 °F to 185 °F) |
| Storage Temperature | -20 °C to 85 °C (-4 °F to 185 °F) |
| Relative Humidity | 0 to 95%, non-condensing |
| Enclosure | NEMA 4X/IP65 |