Specifications and Features

4630 Chlorine Analyzer System

The Signet 4630 Chlorine Analyzer System is an integrated all-in-one system designed to measure free chlorine. The 3-4630-21 chlorine panel with the optional pH sensor is used to accurately calculate free chlorine in applications that have varying pH values (± 0.20 pH units).

In applications where the pH is stable, the pH sensor is not required and the pH value is manually entered into the transmitter to calculate the chlorine levels.

The unique integrated clear flow cell combines sensors, flow regulator, filter and variable area flow indicator in one compact unit. An integrated flow regulator with removable filter accepts inlet pressures of 1 to 8 bar (15 to 120 psi), while maintaining constant flow and minimal pressure to the sensors.

Water flows vertically into sensor tip, eliminating bubble entrapment. The flow cell is designed to maintain a minimum amount of water to ensure sensors stay submerged, even when the system and flow is turned off.

The Signet 4630 Chlorine Analyzer System allows quick setup and easy installation and is supplied with a 100-240 VAC power supply, two 4 to 20 mA outputs and two dry contact mechanical relays. The flow cell accommodates two sensors; one chlorine sensor and an optional pH sensor.

Chlorine:

  • Reagent free measuring
  • Complete panel system allows for quick and easy installation
  • Built-in flow regulator maintains constant flow and pressure to the sensors regardless of inlet pressure

Fields of Application:

  • Water Distribution
  • Ground Water
  • Surface Water
  • Gray Water Dechlorination
  • Food and Beverage
  • HVAC
  • RO Membrane Protection
  • Swimming Pools
  • Aquariums
  • Water Parks

Advantages:

  • EPA 334.0 compliant
  • Reagent-free measuring
  • Complete panel system allows for quick and easy installation
  • Built-in flow regulator maintains constant flow and pressure to the sensors
  • Panel includes a 100-240 VAC power supply, two 4 to 20 mA outputs and two mechanical relays
  • Optional automatic pH compensation (PPM Ranges: 0-2, 0-5 and 0-20)

Standards:

  • CE
  • UL
  • CUL
  • FCC
  • China RoHS

Product Details

  • Manufacturer: GF Signet
  • Part number: 3-4630-20
  • Product type: Transmitter

Review inputs, outputs, power and sensor compatibility.

Specification
Panel MaterialsBlack Acrylic
Flow Cell MaterialsAcrylic
Wiring Enclosure MaterialsPolycarbonate
Flow Cell, Spacer Rings wetted MaterialsAcrylic
Flow Regulator HousingPolycarbonate
Strainer, E-clip, Regulator Spring, FloatStainless Steel
Wetted Materials Valves, VentPolypropylene
Wetted Materials Flow Cell O-rings, DiaphragmEPDM, FKM
Wetted Materials Chlorine ElectrodePVC, PTFE, FPM, Nylon, Silicone
Wetted Materials pH electrodePPS, Glass, UHMW PE, FPM
Wetted Materials plugPolyethylene
Wetted Materials Sealing Tape on Valves, Plug and VentPTFE
System Inlet Pressure Rating1 to 8 bar (15 to 120 psi)
Pressure Regulator< 0.69 bar (10 psi) variation over all ranges of flow and pressure
Flow Tolerance± 15% or rated specification above
Flow Rate Limits30.24 to 45.36 LPH (8 to 12 US gal/h)
Storage Temperature0 to 65° C (32 to 149° F)
Operating Temperature0 to 45° C (32 to 113° F)
pH Range5.0 to 8.5 pH
AC Input - Standard Configuration100 to 240 VAC nominal 50 to 60 Hz, 0.17 A at 100 VAC
DC Input - Optional Configuration12 to 24 VDC ±10% regulated, 250 mA max.
Relative Humidity0 to 95%
Maximum Altitude2000 m (6,562 ft)
EnclosureNEMA 4X (with output wire glands sealed)
TypeChlorine Analyzer
Series4630
Accessories
GF Signet 3-2630-1 Amperometric Chlorine Electrode. Free Chlorine electrode, 0.02 to 2 ppm (mg/l)
GF Signet 3-2630-2 2630 Amperometric Free Chlorine Electrode Materials: CPVC 3-2630-2
GF Signet 3-2630-3 Amperometric Chlorine Electrode. Free Chlorine electrode, 0.02 to 2 ppm (mg/l)
Signet 3-2724-00 PH-ORP Electrode & Sensors 3-2724-00
GF Signet 3-2650-7 Amperometric chlorine electrode. material: pbt, accuracy: < 5 na or 1% of
GF Signet 3-2750-7 DryLoc pH/ORP Sensor Electronics
GF Signet 3-8630-3P Panel mount chlorine and pH transmitter on 8630 Series Chlorine Transmitter
GF Signet 3-4630.390 Rebuild kit-screws, o-rings, boots, (1) filter screen
GF Signet 3-4630.391 Chlorine Flow Cell Pressure Regulator
GF Signet 3-4630.392 Acrylic flow cell complete with all components and connections
GF Signet 3-2630.391 Amperometric Chlorine Electrode. Free Chlorine electrode, 0.02 to 2 ppm (mg/l)
GF Signet 3-2630.392 Replacement membrane, (1) each
GF Signet 3-2630.394 Amperometric Chlorine Electrode. Free Chlorine electrode, 0.02 to 2 ppm (mg/l)
GF Signet 3-2630.396 Electrolyte replacement kit-(2) 30ml electrolyte bottles with syringe, (2)
GF Signet 3-2630.398 Amperometric Chlorine Electrode. Free Chlorine electrode, 0.02 to 2 ppm (mg/l)
GF Signet 3-0700.390 Series: 0700 *pH Buffer kit (1 each 4, 7, 10 pH Buffer in powder form, makes 50
GF Signet 3822-7004 Series: 3822 *pH 4.01 Buffer solution, 1 pint (473 ml) bottle
GF Signet 3822-7007 pH/ORP Buff er Solutions 3822-7007
GF Signet 3822-7010 Series: 3822 *pH 10.00 Buffer solution, 1 pint (473 ml) bottle
GF Signet 3-2700.395 Series: 2700 Calibration kit; includes 3 polypropylene cups, box used as cup