Specifications and Features
8630 Chlorine Transmitter
The Signet 3-8630-3P ProcessPro® Chlorine Transmitter simultaneously displays free chlorine and pH levels on a bright LCD backlight display.
The 8630 Transmitter has two 4 to 20 mA outputs that can be programmed to transmit chlorine, pH or temperature information to a data collection device.
Two dry-contact mechanical relays can be used to deliver an alarm signal or activate a chlorine dosing system.
Programming is simple and easy with Signet's standard 4 button keypad. The menu option allows the use of an optional pH sensor to accurately calculate the free chlorine level or select "Manual pH input" and enter the application's stable pH level to determine free chlorine levels.
Fields of Application:
- Water Distribution
- Ground Water
- Surface Water
- HVAC
- Gray Water Dechlorination
- Food and Beverage
- RO Membrane Protection
- Swimming Pools
- Aquariums
- Water Parks
Advantages:
- Displays free chlorine 0 to 20 ppm (mg/L)
- Two programmable 4 to 20 mA outputs
- Two mechanical relays
- Temperature and pH compensation
- Displays diagnostic information from sensory memory
- Simple setup and easy customization
- Backlit LCD display
Standards:
- CE
- UL
- CUL
- FCC
- RoHS compliant
- China RoHS
Product Details
- Manufacturer: GF Signet
- Part number: 3-8630-3P
- Product type: Transmitter
Review inputs, outputs, power and sensor compatibility.
| Display | LCD Backlit alphanumeric 2 x16 character dot matrix |
|---|---|
| Case Materials | PBT |
| Panel Case Gasket | Neoprene |
| Window | Polyurethane-coated polycarbonate |
| Keypad | Silicone rubber |
| System Operational Ranges ree Cl | 0 to 20 ppm (mg/l) |
| System Operational Ranges ClO 2 | 0 to 2 ppm (mg/l) |
| System Operational pH Range | 4 to 11 pH |
| Power | 12 to 24 VDC ±10%, regulated, 250 mA max. current |
| Sensor Power | 5 VDC ±1% @ 25 °C, regulated |
| Input Specifications | One Digital (S 3 L) input from Amperometric sensor / One Digital (S 3 L) input from pH sensor |
| Output Specifications | Current Loop (2 loops provided) 4 to 20 mA, isolated, adjustable span, reversible with minimum and maximum endpoint adjustment. |
| Update Rate | 300 ms |
| Max Loop Impedance | 50 Ω max. @ 12V/325 Ω max. @ 18V/600 Ω max. @ 24V |
| Relay Outputs | 2 mechanical SPDT contacts: High, Low, Off Pulse, or Window range |
| Maximum Voltage Rating | 5A @ 30 VDC/5 A @ 250 VAC, resistive load |
| Hysteresis | User adjustable |
| Time Delay | Programmable from 0 to 6400 s |
| Operating Temperature | -25 °C to 120 °C (-13 to 248 °F) |
| Storage Temperature | 15 to 80 °C (5 to 176 °F) |
| Relative Humidity | 0 to 95%, non-condensing |
| Max. Altitude | 2000 m (6,562 ft) |
| Enclosure | NEMA 4X/IP65 (front face only) |
| Series | 8630 |
| Type | Chlorine Transmitter |